b'Wiring 10% Voltage Drop $ All Prices in 53Canadian Dollars $Voltage DropUse 10% voltage drop for any noncritical application not affecting the safety of the vessel or its pas-sengers: stereo, cabin lights, fans,etc IMPORTANT! Length (feet): Determined by measuring the length of the conductor from the positive (+) power source connection to the electrical device and back to the negative (-) power source connection. Current (amps): Determined by adding the total amps on a circuit. I = Current - amps L = Length - feet E = Voltage drop at load (in volts)For Example. Q: A bilge pump draws 10 amps. The positive run is 11 feet from the power panel, including the float switch. The negative run is only 10 feet. What size is the wire? A: At 10% the Table B below shows the required wire to be 16awg.Table B10% VOLTAGE DROP AT 12 VOLTSGauge of wire in BLACKLength of WireCurrent (amps)510152025304050607080901001018181816161414121210101010151818161614121210108888201816141412121010888 6625181614 121210108866663018141212101088666644016141210 1088666444501612101088664442260141210886644222270141088666422221 80141088664422211 1001210866642221 10 email: hmp@hollandmarine.comwebsite: www.hollandmarine.comfax:905-891-7972tel:905-891-1639 53'