b'52 $ All Prices in Wiring 3% Voltage DropCanadian Dollars $Voltage DropUse 3% voltage drop for any critical application affecting the safety of the vessel or its passengers: bilge pumps, navigation lights, electronics, etc IMPORTANT! Length (feet): Determined by measuring the length of the conductor from the positive (+) power source connection to the electrical device and back to the negative (-) power source connection. Current (amps): Determined by adding the total amps on a circuit. I = Current - amps L = Length - feet E = Voltage drop at load (in volts)For Example. Q: A bilge pump draws 10 amps. The positive run is 11 feet from the power panel, including the float switch. The negative run is only 10 feet. What size is the wire? A: At 3% the Table A below shows the required wire to be 10awg.Table A3% VOLTAGE DROP AT 12 VOLTSGauge of wire in BLACKLength of WireCurrent (amps)5101520253040506070809010010181412121010886664415161210108866444222014101086664422222512108644422221130121086664422211401086644221002/02/05010664422102/02/04/04/0601066422102/03/03/04/04/07086422102/03/03/04/04/0 8086422102/03/04/04/01008422102/03/04/04/0 52 email: hmp@hollandmarine.comwebsite: www.hollandmarine.comfax:905-891-7972tel:905-891-1639'