b'52 $ All Prices inWiring 3% Voltage DropCanadian Dollars $ Voltage Drop Use 3% voltage drop for any critical application affecting the safety of the vessel or its passengers: bilge pumps, navigation lights, electronics, etcIMPORTANT!Length (feet): Determined by measuring the length of the conductor from the positive (+) power source connection to the electrical device and back to the negative (-) power source connection. Current (amps): Determined by adding the total amps on a circuit.I = Current - ampsL = Length - feetE = Voltage drop at load (in volts)For Example.Q: A bilge pump draws 10 amps. The positive run is 11 feet from the power panel, including the float switch. The negative run is only 10 feet. What size is the wire? A: At 3% the Table A below shows the required wire to be 10awg.Table A 3% VOLTAGE DROP AT 12 VOLTSGauge of wire in BLACK Lengthof Wire Current (amps) 5 10 15 20 25 30 40 50 60 70 80 90 10010 18 14 12 12 10 10 8 8 6 6 6 4 415 16 12 10 10 8 8 6 6 4 4 4 2 220 14 10 10 8 6 6 6 4 4 2 2 2 225 12 10 8 6 4 4 4 2 2 2 2 1 130 12 10 8 6 6 6 4 4 2 2 2 1 140 10 8 6 6 4 4 2 2 1 0 0 2/0 2/050 10 6 6 4 4 2 2 1 0 2/0 2/0 4/0 4/060 10 6 6 4 2 2 1 0 2/0 3/0 3/0 4/0 4/070 8 6 4 2 2 1 0 2/0 3/0 3/0 4/0 4/080 8 6 4 2 2 1 0 2/0 3/0 4/0 4/0100 8 4 2 2 1 0 2/0 3/0 4/0 4/052 email: hmp@hollandmarine.comwebsite: www.hollandmarine.comfax:905-891-7972tel:905-891-1639'