b'Wiring 10% Voltage Drop $ All Prices in53Canadian Dollars $ Voltage Drop Use 10% voltage drop for any noncritical application not affecting the safety of the vessel or its passengers: stereo, cabin lights, fans,etcIMPORTANT!Length (feet): Determined by measuring the length of the conductor from the positive (+) power source connection to the electrical device and back to the negative (-) power source connection. Current (amps): Determined by adding the total amps on a circuit.I = Current - ampsL = Length - feetE = Voltage drop at load (in volts)For Example.Q: A bilge pump draws 10 amps. The positive run is 11 feet from the power panel, including the float switch. The negative run is only 10 feet. What size is the wire? A: At 10% the Table B below shows the required wire to be 16awg.Table B 10% VOLTAGE DROP AT 12 VOLTSGauge of wire in BLACK Lengthof Wire Current (amps) 5 10 15 20 25 30 40 50 60 70 80 90 10010 18 18 18 16 16 14 14 12 12 10 10 10 1015 18 18 16 16 14 12 12 10 10 8 8 8 820 18 16 14 14 12 12 10 10 8 8 86 625 18 16 1412 12 10 10 8 8 6 6 6 630 18 14 12 12 10 10 8 8 6 6 6 6 440 16 14 12 1010 8 8 6 6 6 4 4 450 16 12 10 10 8 8 6 6 4 4 4 2 260 14 12 10 8 8 6 6 4 4 2 2 2 270 14 10 8 8 6 6 6 4 2 2 2 2 1 80 14 10 8 8 6 6 4 4 2 2 2 1 1 100 12 10 8 6 6 6 4 2 2 2 11 0 email: hmp@hollandmarine.comwebsite: www.hollandmarine.comfax:905-891-7972tel:905-891-1639 53'